113 research outputs found

    Material Recognition CNNs and Hierarchical Planning for Biped Robot Locomotion on Slippery Terrain

    Full text link
    In this paper we tackle the problem of visually predicting surface friction for environments with diverse surfaces, and integrating this knowledge into biped robot locomotion planning. The problem is essential for autonomous robot locomotion since diverse surfaces with varying friction abound in the real world, from wood to ceramic tiles, grass or ice, which may cause difficulties or huge energy costs for robot locomotion if not considered. We propose to estimate friction and its uncertainty from visual estimation of material classes using convolutional neural networks, together with probability distribution functions of friction associated with each material. We then robustly integrate the friction predictions into a hierarchical (footstep and full-body) planning method using chance constraints, and optimize the same trajectory costs at both levels of the planning method for consistency. Our solution achieves fully autonomous perception and locomotion on slippery terrain, which considers not only friction and its uncertainty, but also collision, stability and trajectory cost. We show promising friction prediction results in real pictures of outdoor scenarios, and planning experiments on a real robot facing surfaces with different friction

    Mechanism and Control of Anthropomorphic Biped Robots

    Get PDF

    Simulation of an interlocking hydraulic direct-drive system for a biped walking robot

    Get PDF
    Biped robots with serial links driven by an electric motor experience problems because the motor and transmission are installed in each joint, causing the legs to become very heavy. Previous solutions involved robots using servo valves, a type of highly responsive proportional valve. However, high supply pressure is necessary to realize high responsiveness and the resulting energy losses are large. To address this problem, we proposed a hydraulic direct-drive system in which the pump controls the cylinder meter-in flow, while a proportional valve controls the meter-out flow. Furthermore, our hydraulic interlocking drive system connects two hydraulic direct-drive systems for biped humanoid robots and concentrates the pump output on one side cylinder. The meter-in flow rate of the other side cylinder is controlled by the meter-out flow rate of the cylinder on which the pump is concentrated. A comparison of the walking simulation performance with that of the conventional independent system shows that our proposed system reduces the motor output power by 24.3%. These results prove the feasibility of constructing a two-legged robot without having to incorporate highly responsive servo valves

    A Comparison between Two Force-Position Controllers with Gravity Compensation Simulated on a Humanoid Arm

    Get PDF
    The authors propose a comparison between two force-position controllers with gravity compensation simulated on the DEXTER bioinspired robotic arm. The two controllers are both constituted by an internal proportional-derivative (PD) closed-loop for the position control. The force control of the two systems is composed of an external proportional (P) closed-loop for one system (P system) and an external proportional-integrative (PI) closed-loop for the other system (PI system). The simulation tests performed with the two systems on a planar representation of the DEXTER, an eight-DOF bioinspired arm, showed that by varying the stiffness of the environment, with a correct setting of parameters, both systems ensure the achievement of the desired force regime and with great precision the desired position. The two controllers do not have large differences in performance when interacting with a lower stiffness environment. In case of an environment with greater rigidity, the PI system is more stable. The subsequent implementation of these control systems on the DEXTER robotic bioinspired arm gives guidance on the design and control optimisation of the arms of the humanoid robot named SABIAN

    Anatomical calibration through post-processing of standard motion tests data

    Get PDF
    The inertial measurement unit is popularly used as a wearable and flexible tool for human motion tracking. Sensor-to-body alignment, or anatomical calibration (AC), is fundamental to improve accuracy and reliability. Current AC methods either require extra movements or are limited to specific joints. In this research, the authors propose a novel method to achieve AC from standard motion tests (such as walking, or sit-to-stand), and compare the results with the AC obtained from specially designed movements. The proposed method uses the limited acceleration range on medial-lateral direction, and applies principal component analysis to estimate the sagittal plane, while the vertical direction is estimated from acceleration during quiet stance. The results show a good correlation between the two sets of IMUs placed on frontal/back and lateral sides of head, trunk and lower limbs. Moreover, repeatability and convergence were verified. The AC obtained from sit-to-stand and walking achieved similar results as the movements specifically designed for upper and lower body AC, respectively, except for the feet. Therefore, the experiments without AC performed can be recovered through post-processing on the walking and sit-to-stand data. Moreover, extra movements for AC can be avoided during the experiment and instead achieved through the proposed method

    Wavelet thresholding technique for sEMG denoising by baseline estimation

    Get PDF
    The surface electromyography (sEMG) signal is affected by different sources of noises: current technology is considerably robust to the interferences of the power line or cable motion artefacts, but still there are many limitations in denoising the baseline. In this paper, we introduce a new technique, named baseline adaptive denoising algorithm (BADA), for denoising the sEMG signal by wavelet thresholding procedure. In particular, the thresholds are estimated using the same baseline signal with fixed and adaptive techniques. Eventually, we verify that the proposed adaptive method performs better than the standard Donoho technique and different variations, in term of noise cancellation and distortion of the signal, quantified by a new suggested indicator of the denoising quality. Copyright © 2012 Inderscience Enterprises Ltd

    Development of an ultra-miniaturized inertial measurement unit for jaw movement analysis during free chewing

    Get PDF
    Problem statement: Jaw movement analysis, as a clinical aid, can provide an objective basis for understanding and diagnosing jaw musculoskeletal disorders. Therefore, the use and development of devices for quantitatively measuring and analyzing jaw movement have become more common and popular in the clinic. Many types of jaw tracking devices have been developed, but most of them are still not handy and easy to be used. Approach: To improve the handiness and utility of the jaw movement analysis devices, we developed a simple to be used jaw tracking prototype by using a new ultra-miniaturized Inertial Measurement Unit (IMU) named WB-3. The WB-3 IMU was composed by 3-axis gyroscope, 3-axis accelerometer and 3-aixs magnetometer, which can not only measure the acceleration and angular speed of jaw movement, but also can measure mouth opening angle. The IMU's extremely reduced weight and size allowed it to be easily adhered to mandible during normal tests without physical restriction to the subjects. A preliminary experiment for jaw movement analysis during free chewing of three types of food with different shapes and hardness was evaluated. A group of 15 healthy subjects aged from 21-36 years old kindly participated in the experiment. Results: The parameters of chewing time, chewing frequency, power spectrum density of jaw's angular speed and acceleration, cumulative distribution function of jaw's acceleration and mouth opening angle were presented. The experimental results clearly showed that the subjects used less chewing time, less chewing frequency, less acceleration cumulative distribution and energy to eat soft food; higher values were found in the case of hard food and there was no significant difference in mouth opening angle while eating these three foods. Conclusion: Our jaw movement analysis prototype using IMU WB-3 was proved to be a valid and handy method for jaw movement and pattern analysis which may be used clinically as an assistant system for dental therapy. © 2010 Science Publications
    • …
    corecore